Utility trenching & duct bank

Utility Trenching and Duct Bank Installation in St. Louis

Kuesel trenches for and installs underground electrical and telecom conduit, including concrete-encased duct banks, handholes and pull boxes, on commercial, industrial, municipal and data center sites, with union crews from O'Fallon, MO. Call (636) 978-3478.

What we do

  • Utility trenching, bedding and backfill for electrical and MEP subcontractors, so their crews can focus on their installation.
  • Conduit and concrete-encased duct bank installation.
  • Handholes and pull boxes.
  • Conduit runs typically proved clear before backfill and left with pull strings for the electrical contractor.
  • Stub-outs left at the building line, where the electrical trade takes over.

Data center duct bank

On data center campuses, duct bank is often one of the largest underground scopes, and it has to be coordinated with storm, sanitary, water and fire lines running through the same corridors. Our mission critical site work includes generator yard duct banks and hardstands.

How a job runs

  1. 1. Locate existing utilities first: a Missouri 811 locate request, then hydro excavation or potholing where lines are close. See hydrovac excavation.
  2. 2. Excavate and protect the trench: per OSHA 29 CFR 1926 Subpart P, which requires a protective system for trenches 5 ft or deeper unless the trench is in stable rock.
  3. 3. Install conduit and duct bank: to plan depth and spacing, encased as specified.
  4. 4. Prove, backfill and compact: to project specs, with grade set by laser and GPS.

Burial depth, encasement and spacing come from the project drawings, the utility's standards and the NEC (Table 300.5 for minimum cover). The engineer of record sets them, not Kuesel.

Trenchless crossings and directional drilling are coordinated through partner contractors.

Related work: Kuesel as your underground utility contractor, water main installation and fire lines and hydrovac.

FAQ

Do you trench for electrical subcontractors?
Yes. We excavate, shore, bed and backfill the trench so the electrical crew can focus on its installation.
Do you install concrete-encased duct bank?
Yes, along with handholes and pull boxes.
Who sets the depth and encasement?
The project drawings, the utility's standards and the NEC set them, and the engineer of record makes the call, not Kuesel.
Do you do directional drilling?
Trenchless crossings and directional drilling are coordinated through partner contractors.

Sources: OSHA 29 CFR 1926 Subpart P (Excavations) · NFPA 70 NEC Table 300.5 · Missouri One Call System (811)